Description:
CPU blade can be put to default factory settings either by connecting PCPRO or by using the sense switch in the CPU. The best practice to put the CPU to default is by using sense switch.
Procedure to load default data:
Step1: Mount DLC card to “Unit 01” (LENS number is Unit 01+Slot 01+Circuit 01). Then connect Multiline Telephone.
Step2: Change SENSE switch to “A” on CPU Blade.
Step3: Press and release RESET switch on CPU Blade.
Step4: Monitor LED on CPU Blade.
During Default office data: [RUN] lamp is lighting & [SYSD] lamp is blinking.
In case of load default data succeed. [RUN] lamp lights off & [SYSD] lamp lights off and [S2] lamp lights on.
In case of load default Office data is failed : [RUN] lamp lights on and [ALM] lamp lights on.
Step5: Change SENSE switch to “1”.
Step2: Change SENSE switch to “A” on CPU Blade.
Step3: Press and release RESET switch on CPU Blade.
Step4: Monitor LED on CPU Blade.
During Default office data: [RUN] lamp is lighting & [SYSD] lamp is blinking.
In case of load default data succeed. [RUN] lamp lights off & [SYSD] lamp lights off and [S2] lamp lights on.
In case of load default Office data is failed : [RUN] lamp lights on and [ALM] lamp lights on.
Step5: Change SENSE switch to “1”.
Step6: System automatically runs initial itself. [RUN] lamp will blinking.S2 lamp became on.
Step7: Make sure 010101 port is feeding “STN number 300”or “STN number 301”in IP phone.
Step8: Once the data is set to default the IP address of maintenance port is 192.168.1.1 and the VoIP port IP address is 172.16.1.1 if installed.